Rapid identification of Klebsiella pneumoniae isolates from various samples with biosensor and genotyping

dc.contributor.authorSavaş, Sümeyra
dc.contributor.departmentVeteriner Fakültesitr_TR
dc.date.accessioned2021-10-07T07:53:29Z
dc.date.available2021-10-07T07:53:29Z
dc.date.issued2019-09-09
dc.description.abstractThe most important cause of Klebsiella spp. contamination of drinking water is the leakage of animal faeces into drinking water sources. Recently, the biosensor technology has quickly begun to replace other methods with its faster finding and reliability. The aim of this study was to investigate the reliability of the biosensor technology in the rapid detection of Klebsiella pneumoniae (K. pneumoniae) and to determine the presence of the relationship between K. pneumoniae isolates isolated from the drinking water thought to be contaminated by animal faeces and the clinical isolates. For this purpose, portable, microfluidic electrochemical sensor device version 2 (V2) was used for the detection of K. pneumoniae and results were confirmed with VITEK MALDI-TOF Mass Spectrometry (VITEK MS) automated system. For the molecular typing of K. pneumoniae isolates, pulsed-field gel electrophoresis (PFGE) and multiple locus variable-number tandem repeat analysis (MLVA) methods were employed and the results were compared. For these bacteria, the most appropriate typing method was tried to be determined comparatively. PFGE analysis indicated the presence of six different strains, while MLVA divided them into 23 clusters. Clonal relationships were viewed between environmental and clinical isolates. The main goal of this paper is to present, the detailed report of the comparison of the samples isolated from drinking water, animal and human faeces for K. pneumoniae. To accomplish of this goal we introduced that MLVA and PFGE methods. Also, gold nanoparticies enhanced electrochemical biosensor device is used for the determination of K. pneumoniae for the first time.tr_TR
dc.identifier.endpage405tr_TR
dc.identifier.issn/e-issn1308-2817
dc.identifier.issue4tr_TR
dc.identifier.startpage397tr_TR
dc.identifier.urihttps://doi.org/10.33988/auvfd.568339tr_TR
dc.identifier.urihttp://hdl.handle.net/20.500.12575/75291
dc.identifier.volume66tr_TR
dc.language.isoentr_TR
dc.publisherAnkara Üniversitesitr_TR
dc.relation.isversionof10.33988/auvfd.568339tr_TR
dc.relation.journalAnkara Üniversitesi Veteriner Fakültesi Dergisitr_TR
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıtr_TR
dc.subjectBiosensor, K.tr_TR
dc.subjectPneumoniaetr_TR
dc.subjectMLVAtr_TR
dc.titleRapid identification of Klebsiella pneumoniae isolates from various samples with biosensor and genotypingtr_TR
dc.typeArticletr_TR

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
27.pdf
Size:
608.61 KB
Format:
Adobe Portable Document Format
Description:
Dergi
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.62 KB
Format:
Item-specific license agreed upon to submission
Description: